Roxul AFB
AFB® is a light-weight, semi-rigid stone wool batt insulation used for superior sound absorbency and fire resistance.
Applications:
This product is designed for interior wall and floor applications.
Properties:
- Non-combustible stone wool insulation with melting point of approx. 1177°C (2150°F)
- Does not promote smoke or flame spread when exposed to flame
- High density for reduced airflow and sound transmissions
- Water and moisture resistant; does not absorb moisture to maintain insulating value
- Sag-free, tight fits for consistent fire and sound performances
- Range of thicknesses for retrofit and new construction applications
- Variety of wall and floor system configurations available – contact Roxul
- Does not rot, promote mildew, fungi, or bacteria, or sustain vermin
- Earns LEED® points – talk to Roxul’s LEED® Accredited Professional
Technical Data:
| Compliance and Performance: | ||
| CAN/ULC-S702-97 | Stone Fiber Thermal Insulation for Buildings Type 1 | Complies |
| ASTM C 665 | Stone Fiber Blanket Thermal Insulation Type 1 | Complies |
| ASTM C 553 | Stone Fiber Blanket Thermal Insulation | Complies |
| MEA Approval | New York City Approval | 338-97-M |
| City Of Los Angeles approval | RR 25444 | |
| ULC Design Nos. | U311, W406, W408, W419, W423, W440, W441, W442, W508, W600, Z500 | |
| UL Design Nos. | U305, U311, U317, U411, U412, U448, U465, V417, V418, V419 | |
| Fire Performance: | ||
| CAN4 S114 | Test for Non-Combustibility | Non-Combustible |
| ASTM E 136 | Behavior of Materials at 750°C (1382°F) | Non-Combustible |
| CAN/ULC S102 | Surface Burning Characteristics | Flame Spread = 0 Smoke Developed = 0 |
| ASTM E8 (UL 723) | Surface Burning Characteristics | Flame Spread = 0 Smoke Developed = 0 |
| CAN/ULC S129 | Smolder Resistance | 0.09% |
| Acoustical Performance: | ||
| ASTM E 90 | Airborne Sound Transmission Loss | Tested |
| ASTM E 413 | Rating Sound Insulation | Tested |
| ASTM C 423 | Sound Absorption Coefficients | Tested |
| ASTM E 1050 | Impedance and Absorption of Acoustical Materials(Contact Roxul for Rated Wall System Designs) | Tested |
| Air Erosion: | ||
| UL 181 | Maximum Air Velocity | 1000 fpm (5.08 m/s) |
| Thermal Performance: | ||
| ASTM C 518 (C 177) | R-value/inch @ 75°F | 4.1 hr.ft².F/Btu*** |
| RSI value/25.4 mm @ 24°C | 0.72 m²K/W | |
| Corrosive Resistance: | ||
| ASTM C 665 | Corrosiveness to Steel | Pass |
| ASTM C 795 **** | Stainless Steel Stress Corrosion Specification as per Test Methods C871 and C692: U.S. Nuclear Regulatory Commission, Reg. Guide #1.36: U.S. Military Specifications MIL-I-24244 (all versions including B and C) | Conforms |
| Acoustical Performance: | |||||||
| ASTM C423 | |||||||
| CO-EFFICIENTS AT FREQUENCIES | |||||||
| Thickness | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | NRC |
| 1.0" | 0.14 | 0.25 | 0.65 | 0.90 | 1.01 | 1.01 | 0.70 |
| 1.5" | 0.18 | 0.44 | 0.94 | 1.04 | 1.02 | 1.03 | 0.85 |
| 2.0" | 0.28 | 0.60 | 1.09 | 1.09 | 1.05 | 1.07 | 0.95 |
| 3.0” | 0.52 | 0.96 | 1.18 | 1.07 | 1.05 | 1.05 | 1.05 |
| 4.0” | 0.86 | 1.11 | 1.20 | 1.07 | 1.08 | 1.07 | 1.10 |
| Density: | ||
| ≥2” thickness | 2.8 lbs/ft3 45 kg/m3 | |
| Dimensions: | ||
| 16.25” (width) x 48” (length) [412.75 mm (width) x 1219 mm (length)] | ||
| 24.25” (width) x 48” (length) [615.95 mm (width) x 1219 mm (length)] | ||
| Thickness: | ||
| Product thickness is available in 1” to 3.5” with 1/2” increments as well as 4”, 5” and 6” offerings. | ||
For complete technical data, please consult our Technical Library.