FireWall 1HR & 2HR
FireWall® is a non-combustible, rigid stone wool insulation board that is designed for use as a component in Roxul non-combustible steel faced fire wall assemblies where a one or two hour fire rating is required.
Applications:
This product is designed for exterior and interior non-load bearing steel faced fire wall applications where a fire resistance of at least one hour is required.
Two product variations:
FireWall® 1HR holds a fire resistance rating of one hour, from the interior side, as specified in ULC Design No. W605 and UL Design No. U654. In addition, it holds a fire resistance rating of one hour from both sides, as specified in ULC Design No. W610 and UL Design No. U658.
FireWall® 2HR holds a fire resistance rating of two hours, from the interior side, as specified in ULC Design No. W606 and UL Design No. U655. In addition, it holds a fire resistance rating of two hours from both sides, as specified in ULC Design No. W611 and UL Design No. U659.
Properties:
- Lightweight
- Easy to install insulation and construct fire wall design
- Fire resistance at zero lot line clearance
- Non-combustible stone wool insulation
- Dimensionally stable
- Performs over wide temperature ranges
- Energy-saving performance - FireWall® 1HR = R4.2; FireWall® 2HR = R4.3
- Non-corrosive
- Does not rot, promote mildew, fungi, or bacteria
- Earns LEED® points – talk to Roxul’s LEED® Accredited Professional
Technical Data:
| Compliance and Performance: | ||
| ASTM C 612 | Mineral Fiber Block and Board Thermal Insulation | Type IVB, Complies |
| ULC Design Number | FireWall® 1HR: FireWall® 2HR: | W605, W610 |
| UL Design Number | FireWall® 1HR: FireWall® 2HR: | U654, U658 U655, U659 |
| Fire Performance: | ||
| CAN/ULC S114 ASTM E 136 | Test for Non-Combustibility Behavior of Materials at 750ºC (1382ºF) | Non-Combustible Non-Combustible |
| CAN/ULC S102 ASTM E 84 (UL 723) | Surface Burning Characteristics Surface Burning Characteristics | Flame Spread = 0 Flame Spread = 0 |
| Dimensional Stability: | ||
| ASTM C 356 | Linear Shrinkage | <1% @ 1200°F (650°C) |
| Moisture Resistance: | ||
| ASTM C 1104 | Moisture Sorption | 0.04% |
| Thermal Resistance: | ||
| ASTM C 518 (C 177) | R-value/inch @ 75°F FireWall® 1HR: FireWall® 2HR: | 4.2 hr.ft².F/Btu 4.3 hr.ft².F/Btu |
| RSI value/25.4 mm @ 24°C FireWall® 1HR: FireWall® 2HR: | 0.74 m²K/W 0.76 m²K/W | |
| Corrosive Resistance: | ||
| ASTM C 665 | Corrosiveness to Steel | Pass |
| ASTM C 795 | Stainless Steel Stress Corrosion Specification as per Test Methods C871 and C692: U.S. Nuclear Regulatory Commission, Reg. Guide #1.36: U.S. Military Specifications MIL-I-24244 (all versions including B and C) | Conforms |
| Dimensions: | ||
| 24” (610 mm) width x 48” (1219 mm) length | ||
| 31.5” (800 mm) width x 48” (1219 mm) length | ||
| 32” (813 mm) width x 48” (1219 mm) length | ||
| Thickness: | ||
| FireWall® 1HR: | 3” (76 mm) Thickness | |
| FireWall® 2HR: | 4” (102 mm) Thickness | |
For complete technical data, please consult our Technical Library.